Ingenieurbüro Mencke & Tegtmeyer GmbH Vietnam

Introduce Ingenieurbüro Mencke & Tegtmeyer GmbH Vietnam

Mencke & Tegtmeyer Founded in 1993 as a GbR, renamed a GmbH in 2008, we work on improving and increasing the quality of PV systems through our various in-house developments in the field of measuring devices for solar technology.

Our robust and highly precisely calibrated silicon solar radiation sensors are used worldwide by leading manufacturers of PV monitoring systems and inverters. These sensors are supplemented by our temperature sensors for measuring the module and ambient temperature. But also high-quality third-party products such as pyrometers, wind sensors and combined climate sensors are used by us in our own data acquisition systems or offered as a supplier. For the performance measurement of PV modules, we offer different calibrated PV characteristic curve measuring devices, which are used for measurements under natural sunlight as well as under sun simulators, which we offer as flash or continuous light systems for different areas of application.

Our services not only include advice on the combination of ideal sensors, transmitters and data loggers, but also independent planning services for the construction of PV systems.

For many measurements around solar applications Mencke & Tegtmeyer provide a wide range of different products.

We provide consulting to find the best solution for your measurement task as well as composing all required item or planning and construction of complete measurement systems.

  • Solar Irradiance Sensor : Si Sensor & Precise Sensor
  • Temperature Sensor: Ambient & Module
  • Meteorological Sensor: Kipp & Zonen Global Irradiance, Wind Sensors, Climasensor…
  • PV I-V Curve Analyser: PV-KLA, Mini-KLA- Handheld Analyser, PV-KLA MUX, Dark I-V Curve Analyser
  • Sun Simulator: Steady-State Sun Simulator, Flashlight Sun Simulator
  • Xenon Flasher for Power Measurement at PV Module, LED Flashligt Sun Simulator, UniformSun
  • Measuring System: Data Loggers, Transducers, Precise Measuring Systems…

 

  •  
  1. Solar radiation sensors: References for your PV monitoring

https://www.imt-solar.com/solar-irradiance-sensors/

The silicon solar radiation sensor (Si sensor) offers an inexpensive, yet robust and reliable solution for measuring solar irradiance, especially for monitoring photovoltaic (PV) systems. Due to the structure of the sensor element, this corresponds to that of PV modules; these sensors are ideally suited as reference for monitoring PV systems to determine the solar irradiation.

  • Silicon solar radiation sensor for measuring the irradiance (Si sensor)

In particular, the spectral sensitivity corresponding to the PV modules as well as the very similar inclination error (Incident Angle Modifier) ​​enable an exact analysis of PV yields with the help of the sensor readings.

The measurement uncertainty of the Si sensors with temperature compensation is 5 W / qm ± 2.5% of the measured value (determination according to GUM with k = 2, for spectrum AM 1.5 and vertical incidence of light).

All Si sensors have uniform measuring ranges   for the solar irradiance from 0 to 1,500 W / m² and for the internal temperature of the sensor cell from -40 to + 90 ° C.

Type

Supply

Temperature
Compensation

Irradiance Signal 
0…1500 W/sqm

Cell Temperature Signal
-40…+90°C

Si-V-1.5TC-batt / -DMM1

Internal Li-Battery

yes

0...1.5 V

---

Si-V-1.5TC

4...28 Vdc

yes

0...1.5 V

---

Si-V-1.5TC-T

5.5...28 Vdc

yes

0...1.5 V

0...2 V

Si-mV-85

none

no

0...approx. 85 mV

---

Si-mV-85-Pt100 / -4L2

none

no

0...approx. 85 mV

Pt100

Si-mV-85-Pt1000 / -4L2

none

no

0...approx. 85 mV

Pt1000

Si-I-420TC

12...28 Vdc

yes

4...20 mA

---

Si-I-420TC-T

12...28 Vdc

yes

4...20 mA

4...20 mA

Si-V-10TC

12...28 Vdc

yes

0...10 V

---

Si-V-10TC-T

12...28 Vdc

yes

0...10 V

0...10 V

Si-RS485TC-T

12...28 Vdc

yes

RS485

RS485

Si-RS485TC-2T 3

12...28 Vdc

yes

RS485

RS485

Si-RS485TC-T-Tm 4

12...28 Vdc

yes

RS485

RS485

Si-RS485TC-2T-v 5

12...28 Vdc

yes

RS485

RS485

 

 

  • Silicon solar radiation sensor precise sensor with increased accuracy- Smart Pyranometers

Our precise Si sensor is the best choice, especially for applications that require increased accuracy in determining the irradiance (large-scale systems, PR guarantee, R&D).

The sensor can be supplied with an ISFH standard calibration or an ISFH precision calibration, each with a DAkkS certificate.

Product available: SMP11 series, SMP10 series, SMP3 series

  • Equipment sensors for wind speed, module and ambient temperature

Our Si-Sensor Si-RS485TC-2T-v can be expanded with external sensors. The external sensors are connected to the Si sensor via waterproof connectors. The measured values ​​are output via the RS485 interface without further programming. The Vwind-Si sensor for measuring the wind speed and an external temperature sensor can be connected. The Tmodul-Si for the module temperature and the Tamb-Si for the ambient temperature are available as temperature sensors.

Please note that only one temperature sensor can be connected.

Type

Measurements

Measuring range

Cable length

Annotation

Vwind-Si

Wind Speed

0...40 m/s

5 m

Deliver incl. Mounting Angle

Tmodul-Si

Module Temperature

-40...+90°C

3 m

Incl. Double Sided Tape

Tamb-Si

Ambient Temperature

-40...+90°C

3 m

---

Shield Tamb-Si

Weather Protection

---

---

Incl. Mounting Material

 

  • Options for Si sensors

In addition to our standard variants, we also offer customer-specific special solutions.

 

  1. Temperature sensors: for photovoltaic and universal applications

https://www.imt-solar.com/temperature-sensors/ambient-temperature/

Our temperature sensors are available as ambient temperature, surface or module temperature sensors with various output signals.

The sensors are offered with a robust aluminum housing, robust connection cable, uniform output and delivery with a calibration protocol.

  • Ambient temperature sensors

Type

Supply

Output Signal

Measuring Range

Ta-Pt100

---

Pt100

-40...+80°C

Ta-Pt1000

---

Pt1000

-40...+80°C

Ta-ext-Pt10001

---

Pt1000

-40...+80°C

Ta-V-4090

12...28 Vdc

0...10 V

-40...+90°C

Ta-I-4090

12...28 Vdc

4...20 mA

-40...+90°C

Ta-ext-V-40901

12...28 Vdc

0...10 V

-40...+90°C

Ta-ext-I-40901

12...28 Vdc

4...20 mA

-40...+90°C

Ta-ext-RS4851

10...28 Vdc

RS485

-40…+90°C

1 - Ta-ext-XXX: With external Pt1000 sensor with 3 m cable

Note about digital temperature sensor
Suffix -MB in type designation: Modbus protocol
Suffix -MT in type designation: M&T protocol

  • Module temperature sensors

Type

Supply

Output Signal

Measuring Range

Tmodul

---

Pt100

-50...+150°C

Tm-Pt1000

---

Pt1000

-40...+90°C

Tm-Pt1000-Box1

---

Pt1000

-40...+90°C

Tm-V-4090

12...28 Vdc

0...10 V

-40...+90°C

Tm-I-4090

12...28 Vdc

4...20 mA

-40...+90°C

Tm-RS485

10...28 Vdc

RS485

-40...+90°C

1 for Tm-Pt1000-Box: Preconfigurated with Aluminium case with clamps inside for four wire connection.

Note about digital temperature sensor
Suffix -MB in type designation: Modbus protocol
Suffix -MT in type designation: M&T protocol

 

  1. Meteorological sensors:  from low-cost to high-end

https://www.imt-solar.com/products/meteorological-sensors/

We offer you sensors for almost all measured variables in meteorology. We only use high-quality products from well-known manufacturers. Depending on your requirements, you can choose from a wide range of sensors with different specifications. The offers range from simple sensors at an affordable price to highly precise and very high quality sensors with a very good price-performance ratio.

We can provide you with individual meteorological sensors as well as extensive accessories such as brackets, mounting material and lightning protection technology. On request, we can also offer you complete meteorological stations.

  • Pyranometer from Kipp & Zonen:  for measuring the irradiance

Type

Iso Classification

Output Signal

CMP 3

Second Class

5 to 20 μV/W/sqm

CMP 6

First Class

5 to 20 μV/W/sqm

CMP 10/11

Secondary Standard

7 to 14 μV/W/sqm

CMP 21/22

Secondary Standard

7 to 14 μV/W/sqm

SMP 3

Second Class

RS485 / 1 V or 20 mA

SMP 6

First Class

RS485 / 1 V or 20 mA

SMP 10/11

Secondary Standard

RS485 / 1 V or 20 mA

SMP 21/22

Secondary Standard

RS485 / 1 V or 20 mA

 

  • Wind transmitter: in various designs

Wind Velocity- Vwind-420- ADOLF THIES

  • Measuring Range:           Max. 50 to 75 m/s
  • Error:     1% to 5%
  • Output Signal:   
    • - Impulse (Reed-Relais, Open Collector)
    • - 1, 5 or 10 V
    • - 0...20 mA, 4...20 mA
    • - RS485
  • Versions:             - Cupstar Anemometer & - Ultrasonic

 

Model available:

Order - No.

ADOLF THIES

Electrical

Output

Measuring range

Heating power

Connection

4.3519.00.140

4.3519.00.840 (1)

0...20mA

0...50m/s

20W

12m Cable LiYCY 6 x 0,25mm²

4.3519.00.141

4...20mA

0...50m/s

20W

12m Cable LiYCY 6 x 0,25mm²

4.3519.00.161

0...10V

0…50m/s

20W

12m Cable LiYCY 6 x 0,25mm²

4.3519.00.167

0...2V

0…50m/s

20W

12m Cable LiYCY 6 x 0,25mm²

4.3519.00.173

0...5V

0…50m/s

20W

12m Cable LiYCY 6 x 0,25mm²

4.3519.00.361

0...10V

0…3m/s max. 13,8V

@ 3m/s

20W

12m Cable LiYCY 6 x 0,25mm²

4.3519.00.441

4...20mA

0…40m/s

20W

3m PUR -Cable 6 x 0,25mm²

4.3519.00.641

4...20mA

0…60m/s

20W

12m Cable LiYCY 6 x 0,25mm²

4.3519.00.740

0…20mA

0…50m/s

20W

7 pol. Plug

4.3519.00.741

4...20mA

0…50m/s

20W

7 pol. Plug

4.3519.00.761

0...10V

0...50m/s

20W

7 pol. Plug

4.3519.00.773

0...5V

0...50m/s

20W

7 pol. Plug

4.3519.00.961

0...10V

0…15m/s

20W

12m Cable LiYCY 6 x 0,25mm²

4.3519.01.140

0...20mA

0…50m/s

20W

1,5 -3m Spiral Cable LiYY 6 x 0,14mm²

4.3519.02.141

4...20mA

0…50m/s

10W

2m Cable 6 x 0,56mm²

4.3519.04.441

4...20mA

0…40m/s

20W

0,95m PUR- Cable 6 x 0,25mm²

4.3519.05.141

4...20mA

0…50m/s

20W

15m Cable LiYCY 6 x 0,25mm²

4.3519.05.161

0…10V

0…50m/s

20W

15m Cable LiYCY 6 x 0,25mm²

4.3519.05.641

4...20mA

0…60m/s

20W

15m Cable LiYCY 6 x 0,25mm²

4.3519.10.441

4...20mA

0…40m/s

Without heating

12m Cable LiYCY 6 x 0,25mm²

4.3519.20.141

4...20mA

0...50m/s

10W

12m Cable LiYCY 6 x 0,25mm²

4.3519.39.141

4...20mA

0…50m/s

20W

12m Cable LiYCY 6 x 0,25mm²

with cable lug at the shield

4.3519.40.140

0...20mA

0...50m/s

60W

12m Cable LiYCY 6 x 0,5mm²

4.3519.40.141

4...20mA

0...50m/s

60W

12m Cable LiYCY 6 x 0,5mm²

4.3519.40.161

0...10V

0…50m/s

60W

12m Cable LiYCY 6 x 0,5mm²

4.3519.40.167

0...2V

0…50m/s

60W

12m Cable LiYCY 6 x 0,5mm²

4.3519.40.173

0...5V

0…50m/s

60W

12m Cable LiYCY 6 x 0,5mm²

4.3519.40.740

0…20mA

0…50m/s

60W

7 pol. Plug

4.3519.40.741

4...20mA

0…50m/s

60W

7 pol. Plug

4.3519.40.761

0...10V

0...50m/s

60W

7 pol. Plug

4.3519.41.741

4...20mA

0...75m/s

110W

7 pol. Plug

4.3519.41.742

4…20mA

0...50m/s

110W

7 pol. Plug

1) Counter nut inverse-mounted, see figure 6.

Wind Direction- Rwind-420- ADOLF THIES

  • Measuring Range             10...350° to 0...360°
  • Error      2...5°
  • Resolution           0.5...45°
  • Output Signal    
    • Gray-Code 2, 3 or 4 bit (Open Collector)
    • 8 bit serial
    • Resistance
    • 1, 5 or 10 V
    • 0...20 mA, 4...20 mA
    • RS485
  • Version - Wind Vane &  Ultrasonic

 

Model available:

Order - No.

ADOLF THIES

Meas. range

Electr. Output

Heating

Operating

Voltage

Connection

4.3129.00.140

4.3129.00.840*

0...360°

0...20 mA

20 W

15...30 V DC or 24 V AC

12 m cable LiYCY 6 x 0,25 mm²

4.3129.00.141

0…360°

4...20 mA

20 W

15...30 V DC or 24 V AC

12 m cable LiYCY 6 x 0,25 mm²

4.3129.00.161

0...360°

0...10 V

20 W

15...30 V DC or 24 V AC

12 m cable LiYCY 6 x 0,25 mm²

4.3129.00.167

0…360°

0…2 V

20 W

8...30 V DC or 24 V AC

12 m cable LiYCY 6 x 0,25 mm²

4.3129.00.173

0…360°

0…5 V

20 W

8...30 V DC or 24 V AC

12 m cable LiYCY 6 x 0,25 mm

4.3129.00.740

0…360°

0…20 mA

20 W

15…30 V DC or 24 V AC

7 pole plug

4.3129.00.741

0…360°

4...20 mA

20 W

15...30 V DC or 24 V AC

7 pole plug

4.3129.00.761

0…360°

0…10 V

20 W

15...30 V DC or 24 V AC

7 pole plug

4.3129.00.767

0…360°

0.…2 V

20 W

8...30 V DC or 24 V AC

7 pole plug

4.3129.00.773

0…360°

0.…5 V

20 W

8...30 V DC or 24 V AC

7 pole plug

4.3129.00.940

0…360°

0...20 mA

20 W

15...30 V DC or 24 V AC

12 m cable LiYCY 6 x 0,25 mm²

4.3129.00.941

0…360°

4...20 mA

20 W

15...30 V DC or 24 V AC

12 m cable LiYCY 6 x 0,25 mm²

4.3129.02.141

0…360°

4...20 mA

10 W

15...30 V DC or 24 V AC

2 m cable 6 x 0,56 mm²

4.3129.04.767

0…360°

0.…2 V

20 W

8...30 V DC or 24 V AC

7 pole plug

4.3129.05.140

0…360°

0...20 mA

20 W

15...30 V DC or 24 V AC

15 m cable LiYCY 6 x 0,25 mm

4.3129.05.141

0…360°

4...20 mA

20 W

15...30 V DC or 24 V AC

15 m cable LiYCY 6 x 0,25 mm²

4.3129.05.161

0…360°

0...10 V

20 W

15...30 V DC or 24 V AC

15 m cable LiYCY 6 x 0,25 mm²

4.3129.39.141

0…360°

4...20 mA

20 W

15...30 V DC or 24 V AC

15 m cable LiYCY 6 x 0,25 mm²

with cable lug at the shield

 

  • Climate sensors: Ultrasonic measurement principle

Type

Measured Parameter

Climasensor US WIND

4.9203.00.00X1

Wind Speed and Direction

Climasensor US TFB

4.9201.00.00X

Wind Speed and Direction, ambient Temperature, Humidity and Air Pressure

Climasensor US NH

4.9202.00.00X

Wind Speed and Direction, Precipitation, Type of Precipitation and Brightness

Climasensor US NHTFB 4.9200.00.00X

Wind Speed and Direction, Precipitation, Type of Precipitation and Brightnes, ambient Temperature, Humidity and Air Pressure

 

  • Other meteorological sensors:
  • Solare Irradiance
  • Wind Velocity
  • Wind Direction
  • Air Temperature
  • Relative Humidity
  • Air Pressure
  • Precipitation Amount

 

  1. Characteristic curve measuring devices: for photovoltaic modules and generators

https://www.imt-solar.com/products/pv-i-v-curve-analysers/

For numerous applications in photovoltaic in research, development and production, we offer you various characteristic curve measuring devices

  • PV-KLA: Characteristic curve measurement for PV modules and cells

Basic Accuracy

0,1% from Fullscale

Resolution

16 Bit

Sampling

Simultaneous Sampling of U, I and G

Voltage Ranges

50, 100 and 200 V
50 and 100 V in Conjunction with Flasher

Current Ranges

4, 8, 16 and 32 A

Irradiance Range

1300 W/sqm

Temperature Range

0 to 75°C

Maximum Sampling Rate

50 000 samples/s

Duration of Curve Measuring

2 to 500 ms

Maximum Measuring Rate

6 Curves per Minute

Supply

5-V Wall Plug Transformer

Port

USB 2.0

Handling

Control with PC and Software PVK

Delivery Content

PV-KLA, Measuring Cable, Irradiance Sensor, Temperature Sensor,
Wall Plug Transformer, Software, Handbook, Transportation Case

Options

- Customized Ranges
- 0-V Option for optimized Isc Measurement
- I-V Curve Measurement of PV Cells
- Remote Control of PVK via TPC/IP
- Flash Trigger
- Sampling Rate up to 250 000 samples/s
- Self-Contained Supply with Accu

 

  • Mini-KLA: Handheld measuring device for PV modules

Basic Accuracy

0,4% from Fullscale

Voltage Ranges

30, 60 and 120 V

Current Ranges

4 and 8 A

Irradiance Range

1300 W/sqm

Temperature Range

-20 to +70°C

Choice of Measuring Range

automatic

Choice of Resolution

automatic

Maximale Sampling Rate

45000 samples/s

Resolution LC-Displays

128 * 64 Pixel

Handling

2 Buttons

Voltage Supply

5 V, 4 * Mignon Accu

Port

RS232

Delivery Content

Mini-KLA, Si-V-1.5TC-T, Measuring cable, Accu, Charging unit, Software MiniLes, Handbook, Transportation Case

Options

- Current Range up to 16 A
- 4 Cabel Measurement

 

  • PV-KLA MUX: Fully automated PV module measuring stand

I-V Curve Measurment

see Specification PV-KLA

Number of PV Module

4 to 128 (max. 32 recommended)

Irradiance

Solars Irradiance Sensor

Module Temperature

One Module Temperature Sensor per Module

Meteorology

10-V Input(12 bit) for Meteorological Sensor

Handling

Touchscreen, Keyboard

Case

Case for Outdoor Use

Options

- Customized Voltage and Current Ranges, Zero-Volt Option
- Additional Mnalog Inputs
Meteorological Sensors as Pyranometer for Global and Diffus Irradiance, Wind Volcity and Direction, Ambient and Module Temperature
- Air Conditioner
- Additional Sensor for Module Temperature
- 19 bit Datalogging System for Additional Meteorological Sensor (Universal Inputs)

 

  • Dark characteristics KLA: Dark curve measurement for PV modules

Voltage Range

up to 120 V

Current Range

up to 20 A

Temperature Range

0 to 75°C

Duration of Measurement Intervall

appr. 10 s

 

  1. Solar simulators: for photovoltaic and solar thermal

https://www.imt-solar.com/products/sun-simulators/

Our solar simulators are used in photovoltaic as flash light (flasher) or continuous light devices (steady state) for the performance measurement of PV modules in production, research and development, for light aging tests (light soaking) and in teaching.

Due to the universal application possibilities, the continuous light simulators can also be designed as combination devices for both photovoltaic and solar thermal applications.

  • SUSI Steady state solar simulators: In photovoltaic and solar thermal
  • Solarflare - Xenon flashlight solar simulators: performance measurement of PV modules  including: Solar Flare- Flashing light System, PV-Kla I-V Curve analyser for Photovoltaics, SI-01TXeXT Silicon Irradiance Sensor
  • Solarflare- LED flashlight solar simulators: the performance measurement of PV modules
  • UniformSun - Homogeneity measuring system: for solar simulators

 

  1. Measuring technology: From components to a complete system

https://www.imt-solar.com/products/measuring-systems/

We offer you the complete range of measurement systems and components, starting with the delivery of a wide variety of sensors, transmitters and data loggers to planning, manufacturing and setting up complex measurement systems.

  • COMBILOG 1022  Data logger- THEODOR FRIEDRICHS  - 1022.2000 : With multifunctional entrances
  • UgT-MU / IgT-MU, Voltage and Current Transducers: For versatile applications
  • EZW, Energy countr of alternating voltage
  • EZD, Energy counter for thee phase current
  • DIw-MU, Plug-in current transformer 50A
  • Shunt resistors for dc current measurement
  • SW2010, Current transducer alternating current
  • PV Monitoring : For photovoltaic as well as universal use
List code tham khảo thêm tại Jon & Jul
Liên hệ tư vấn ngay: 0385 546 492
Email: An@jon-jul.com
Kho Tự Động Hóa Jon & Jul
Văn phòng đại diện: Số 4 Đường 14, Quốc Lộ 13, Khu Đô Thị Vạn Phúc , Phường Hiệp Bình Phước, Thành phố Thủ Đức, Thành phố Hồ Chí Minh, Việt Nam.