AUF752 Alia Viet Nam
Price: Contact
Brand: (Raytek) Fluke Process Instrument
Category: Detect Fire Detector
Supplier: Jon&Jul Việt Nam
Origin:
Ứng dụng sản phẩm: Electronic
AUF752 Time-based ultrasonic flowmeter Alia Vietnam
Introducing AUF752 Alia Vietnam
The AUF752 series is a permanently mounted transit time ultrasonic flowmeter. It features clamp-type probes for non-invasive measurement of clean homogeneous fluid processes. This user-friendly, microprocessor-based, field-programmable flow meter ensures that existing process flow can be carried out without interrupting the flow and at very low installation costs.
Features of AUF752 Alia Vietnam
- 2-line LCD display with flow rate, total counter…
- Store up to 720 hours / 365 days / 36 months / 10 years Total value
- Wide range velocity 0.01 ~ +/- 32 m/s
- Probe for pipe sizes from 25-4000 mm
- High accuracy +/- 0.5% of reading
- Various output types like 4-20 mA, pulse, RS485, HART
- With self-calibration function, real-time measurement calibration
- Accurate and stable measurement
- Optional dual channel flowmeter, more accurate and reliable measurement
- The sensor has high temperature resistance and long lifespan, It can reach 200°C in a short time
Technical specifications AUF752 Alia Vietnam
| Measurement principles | : | Shipping time difference |
| Pipe size | : | Type NN : 25-4000 mm (1"-160") |
| : | HT type : 25-4000 mm (1"-160") | |
| Pipe material | : | Cast iron, stainless steel, ductile iron |
| Copper, PVC, Aluminum, Fiberglass, etc | ||
| Lining material | : | Tar Epoxy, Rubber, Mortar, Polypropylene, Polystyrol, |
| Polyethylene, Teflon, vv | ||
| Sensor housing | : | SS 304 |
| Temperature | : | NN sensor: -40 ~ 70°C |
| : | HT sensor: -40 ~ 160°C | |
| Display | : | 2-line LCD with backlight |
| Flow | : | 7 digits with decimal point |
| total | : | 8 digits, forward, reverse and net value. |
| Technical unit | : | m 3 , L, USgal, USbbl, ft 3 |
| Time unit | : | seconds, minutes, hours, days |
| Energy unit | : | xe/h, Kcal/h, Mcar/h, MJ/h, GJ/h, BTU/h |
| Other | : | Velocity, Date, Time, Signal Status. |
| Accuracy | : | +/-1% ~ +/-1.5% of reading (0.5-30 m/s) |
| : | +/- 0.5% of reading (Online calibration) | |
| Repeatability | : | +/- 0.2% of reading |
| Input 4-20 mA | : | 2 points, programmable |
| Function | : | Temperature. Thermal energy measurements |
| Keyboard | : | 16 tactile keys |
| Response time | : | Less than 1 second |
| Flow velocity | : | 0,01 ~ +/- 32 m/s |
| Resolution | : | 0,001 m/s |
| Ambient temperature | : | -20~50°C |
| Mount | : | Wall mounted |
| Max. Cable length | : | 100 m |
| Energy consumption | : | Less than 3W |
| Power supply | : | 90-260 VAC 50/60 Hz and 24 VDC +/- 10% |
| Data saving | : | Operating parameters and totalizer |
| figures stored by EEPROM for more information | ||
| more than 10 years | ||
| Output current | : | 4-20 mA |
| Pulse output | : | 1 unit/pulse |
| Rating | : | 12-24 VDC, 50 mA max. |
| Communicate | : | RS485 (MODBUS) (Standard) |
| : | HART (Compatible) (Optional) | |
| Size | : | 270*185*67mm |
| Weight | : | 2 kg |
| Protection class | ||
| Adapter | : | IP65 |
| Sensor | : | IP68 (Submersible) |