Overview of MGBS-P-L1HE-AR-UR-SH-160520 Euchner Safety Lock
- Lock module with handle module
- Suitable for right-hand hinged doors
- Serial connection possible (up to 20 AR devices in series)
- Short circuit monitoring
- 2 safety outputs (semiconductor outputs)
- Up to class 4/PL e according to EN ISO 13849-1
- Dừng khẩn cấp
- 2 nút bấm (có đèn)
- Với đầu nối M23
- bảng mã Unicode
- Đầu ra giám sát vị trí cửa
- bao gồm nhả thoát hiểm và tay nắm cửa bên trong
Thông số kỹ thuật MGBS-P-L1HE-AR-U-R-SH-160520 Khóa an toàn Euchner
Mechanical values and environment
Installation orientation | any |
Mechanical life | 1 x 10⁶ |
Ambient temperature | -20 ... +55 °C |
Material | |
Housing | Die-cast zinc, stainless steel powder-coated, brass |
Miscellaneous
Additional feature | with silver-colored handle |
Mechanical values and environment
Installation orientation | Door hinge DIN right |
Degree of protection | IP65 |
Ambient temperature | -20 ... +55 °C |
Material | |
Housing | Fiber glass reinforced plastic, nickel-plated die-cast zinc, stainless steel |
Miscellaneous
Product version number | V1.0.0 |
Additional feature | with automatic lockout mechanism |
Locking modules MGBS-P-L1-AR-U-R-AEE-SH-159086 (Order
Workspace
Repeat accuracy R | |
according to EN 60947-5-2 | 10 % |
Operating and display elements
Item | Color | Extras | Slide-in label | Note slide-in label | Version | Switching element | Number | Designation1 | LED |
---|---|---|---|---|---|---|---|---|---|
1 | Emergency stop | 2 PD | |||||||
2 | Illuminated pushbutton | 1NO | |||||||
3 | Illuminated pushbutton | 1NO |
Electrical connection values
Fuse | |
external (operating voltage UB) | 0.25 ... 8 A |
external (solenoid operating voltage IMP) | 0.5 ... 8 A |
Power consumption | 6 W |
Rated insulation voltage Ui | 50 V |
Rated impulse withstand voltage Uimp | 0.5 kV |
Operating voltage DC | |
UUB | 24 V DC -15% ... +15% reverse polarity protected, regulated, residual ripple<5%, PELV |
EMC protection requirements | Acc. to EN IEC 60947-5-3 |
Utilization category | |
DC-13 | 24 V 150 mA |
Solenoid operating voltage DC | |
UIMP | 24 V DC -15% ... +10% reverse polarity protected, regulated, residual ripple<5%, PELV |
Solenoid duty cycle | 100 % |
Risk time according to EN 60947-5-3 | max. 260 ms |
Risk time according to EN 60947-5-3, extension for each additional device | max. 5 ms |
Switching load | |
according to UL | 24V DC, Class 2 |
Safety class | |
EN IEC 61140 | III |
Current consumption | |
IUB | 40 mA |
IIMP | 400 mA |
Test pulse duration | max. 1.0 ms |
Test pulse interval | min. 140 ms |
Degree of contamination (external, according to EN 60947-1) | 3 |
Controls and indicators | |
Operating voltage | UB V |
Operating current | 1 ... 50 mA |
Power supply | |
LED | 24 V |
Current consumption | |
LED | 10 mA |
Emergency stop | |
Operating voltage | 5 ... 24 V |
Operating current | 1 ... 100 mA |
Monitoring output OD, OI | |
Output type | p-switching, short circuit-proof |
Output voltage | 0.8xUB ... UB V DC |
Switching current | 1 ... 50 mA |
Safety outputs FO1A / FO1B | |
Output type | 2 semiconductor outputs, p-switching, short circuit-proof |
Output voltage | |
HIGH U(FO1A) / U(FO1B) | UB-1.5 ... UB V DC |
LOW U(FO1A) / U(FO1B) | 0 ... 1 V DC |
Discrepancy time | |
both safety outputs | max. 10 ms Acc. to EN IEC 60947-5-3 |
Turn-on time | max. 400 ms |
Off-state current Ir | max. 0.25 mA |
Switching current | |
per safety output FO1A / FO1B | 1 ... 150 mA |
Mechanical values and environment
Approach speed | max. 20 m/min |
Connection type | 1 plug connector M23, 19-pin, RC18 |
Extraction force | 20 N |
Ready delay | 8 s |
Actuating force | 10 N |
Installation orientation | Door hinge DIN right |
Switching frequency | max. 0.5 Hz |
Mechanical life | 1 x 10⁶ |
Overtravel | 5 mm |
Retention force | 20 N |
Shock and vibration resistance | Acc. to EN IEC 60947-5-3 |
Degree of protection | IP65 |
Ambient temperature | |
at UB = 24 V DC | -20 ... +55 °C |
Material | |
Switch bracket | Die-cast zinc |
Safety switch housing | Reinforced thermoplastic |
Locking force Fmax | 3900 N |
Locking force FZh | 3000 N |
Guard locking principle | Closed-circuit current principle |
Characteristic values according to EN ISO 13849-1 and EN IEC 62061
Mission time | 20 y |
Emergency stop | |
B10D | 0.13 x 10⁶ |
Monitoring of guard locking and the guard position | |
Category | 4 |
Performance Level | PL e |
PFHD | 4.1 x 10 -9 |
Miscellaneous
The following applies to the approval according to UL | Operation only with UL Class 2 power supply or equivalent measures; see operating instructions |