CES-I-BP-M-C07-SB-160076 Euchner door lock set

Overview of CES-I-BP-M-C07-SB-160076  Euchner Safety Switch

  • Safety switch with integrated rating electronics
  • Suitable for discrete operation (no serial connection)
  • Multicode
  • M12 plug connector, 5 pin
  • With OD door monitoring output
  • Diagnosis via IO-Link with ESM-CB safety module
  • 2 safety outputs (semiconductor outputs)
  • Short circuit monitoring
  • Type 4/PL e according to EN ISO 13849-1
  • Three dynamic faces

Specifications CES-I-BP-M-C07-SB-160076 Euchner safety switch

Workspace

Repeat accuracy R  
according to EN 60947-5-2 <= 10

Electrical connection values

Fuse  
external (operating voltage) 0.25 ... 8 A
rated conditional short-circuit current 100 A
Rated insulation voltage Ui 300 V
Rated impulse withstand voltage Uimp 1.5 kV
Operating voltage DC  
UB 24 V DC -15% ... +15% regulated, residual ripple<5%, PELV
Turn-on time  
Safety outputs max. 100 ms
EMC protection requirements Acc. to EN IEC 60947-5-3
Risk time according to EN 60947-5-3 max. 125 ms
Safety class III
Current consumption 40 mA
Degree of contamination (external, according to EN 60947-1) 3
  Monitoring output OD/C
Output type p-switching, short circuit-proof
Output voltage UB-1.5 ... UB V DC
Switching current 1 ... 50 mA
  Safety outputs FO1A / FO1B
Output type Semiconductor outputs, p-switching, short circuit-proof
Output voltage  
LOW U(FO1A) / U(FO1B) 0 ... 1 V DC
HIGH U(FO1A) / U(FO1B) UB-1.5V ... UB V DC 
Discrepancy time max. 10 ms
Utilization category  
DC-13 24 V 150 mA 
Off-state current Ir max. 0.25mA
Switching current 1 ... 150 mA
Test pulse duration 0.3 ms 
Test pulse interval ca 100 ms

Mechanical values and environment

Dimensions 40 x 26.5 x 18
Connection type M12 plug connector, 5-pin
Tightening torque max. 0.8 Nm
Ready delay 5 s
Operating altitude max. 4 000 m
Installation orientation any
Switching frequency max. 1 Hz
Mounting distance  
between 2 switches or 2 actuators min. 50 mm
Mounting type Surface mounting on metal
Shock and vibration resistance Acc. to EN IEC 60947-5-3
Degree of protection IP65/IP67/IP69/IP69K
Ambient temperature  
at UB = 24 V DC -25 ... +55 °C 
Material  
Housing Plastic, PBT-PC-GF30

Characteristic values according to EN ISO 13849-1 and EN IEC 62061

Mission time  
according to EN ISO 13849-1  
SIL CL  
according to EN 62061:2005/A2:2015  

Characteristic values according to EN ISO 13849-1 and EN IEC 62061

  PL Maximum SIL PFHD Category Mission time
Monitoring of the guard position PL e 3 6x10-10 4 20 and

 

Miscellaneous

The following applies to the approval according to UL Operation only with UL Class 2 power supply or equivalent measures
Additional feature Caps included

In combination with actuator CES-A-BDN-06-158210, CES-A-BTN-C07-156230

Switching hysteresis 1 ... 2 mm

In combination with actuator CES-A-BDN-06-158210

Switch-on distance  
Installation position C 8 mm
Installation position A 16 mm
Installation position B 11 mm
Installation position D 7 mm
Secured switch-off distance sar  
in x direction/installation position C max. 21 mm
in x direction/installation position A max. 24 mm
Secured switching distance sao  
in x direction/installation position C min. 6 mm
in x direction/installation position A min. 13 mm

In combination with actuator CES-A-BTN-C07-156230

Switch-on distance  
Installation position A + B 13 mm
Installation position C + D 7 mm
Secured switch-off distance sar  
in x direction/installation position A + B max. 20 mm
in x direction/installation position C + D max. 17 mm
Secured switching distance sao  
in x direction/installation position A min. 10 mm
in x direction/installation position B min. 9 mm
in x direction/installation position D min. 2 mm
in x direction/installation position C min. 3 mm

Related information Euchner

- > See more Euchner  products here 

-> See more products  here