MGB L0 APA AA1A2 S1 R 112596 Euchner Viet Nam
Price: Contact
Brand: Euchner
Category: Multi-function Lock
Supplier: Jon&Jul Việt Nam
Origin: Germany
Ứng dụng sản phẩm: Mechanical
Interlock MGB L0 APA AA1A2 S1 R 112596 Euchner Vietnam
Introduction Interlock MGB L0 APA AA1A2 S1 R 112596 Euchner Vietnam
Interlock module MGB-L0-APA..., without controller or indicator, RC18, on mounting plate
-
Interlock (no security lock)
-
With RC18 connector
-
Mounts on mounting plate
-
Unicode code table
Security lock type
MGB-L0... |
The bolt blade in the handle module is moved in and out of the interlock module by activating the door handle. The door handle is not locked in the locked position. |
Door hinge
The mechanical door stop is permanently integrated into the evaluation module of the MGB. Marking on the stop makes adjustment easier.
Instruction
LED indicators show all important system and status information.
Monitor output
FROM |
ON when door is closed |
OT |
The bolt blade is installed into the evaluation module |
Oh |
Diagnose; there is an error |
Notice
The interlock module is pre-assembled on the mounting plate.
Technical specifications Interlock MGB L0 APA AA1A2 S1 R 112596 Euchner Vietnam
Operational and display elements
Electrical connection value
Rated insulation voltage U i |
30 V |
Rated impulse withstand voltage U imp |
1,5 kV |
Time difference |
|
between FO1A and FO1B |
max. 10 milliseconds |
Category of use |
|
DC-13 |
24V 200mA |
Risk period according to EN 60947-5-3 |
max. 350 milliseconds |
Safety class |
III |
Transponder encryption |
Unicode encoding |
Pollution level (external, according to EN 60947-1) |
3 |
|
Monitor OD, OT, OL, OI output |
Output type |
Semiconductor output, p-switched, short-circuit protection |
Output voltage |
UA-2V...UA V DC |
Output current |
max. 50 mA |
|
Safety output FO1A, FO1B |
Output type |
Semiconductor output, p-switched, short-circuit protection |
Output voltage |
|
U FO1A /U FO1B HIGH |
UB-2V...UBVDC |
U FO1A /U FO1B LOW |
0 ... 1 V DC |
Output current |
|
per safety output FO1A/FO1B |
1 ... 200 mA |
Check pulse duration |
max. 0.3 milliseconds |
Check the pulse interval |
minute. 100 milliseconds |
|
U A power source |
DC operating voltage |
|
you |
24V DC -15%... +10% |
Current consumption |
|
I UA |
max. 10 mA |
|
U B power source |
DC operating voltage |
|
U B |
24V DC -15%... +10% |
Current consumption |
|
I UB |
max. 80 mA |
Mechanical and environmental value
Connection type |
RC18 connector |
Installation direction |
Right DIN door hinge |
Switch frequently |
0,25 Hz |
Mechanical life |
|
in case of use as a door stopper and 1 Joule impact energy |
0,1 x 10⁶ |
|
1 x 10⁶ |
Protection level |
IP65 |
Ambient temperature |
|
at U B = 24 V DC |
-20 ... +55 ° C |
Material |
|
House |
Fiberglass reinforced plastic; nickel-plated die-cast zinc; Stainless Steel |
Characteristic values according to EN ISO 13849-1 and EN IEC 62061
|
PL |
Maximum SIL |
PFH D |
Type |
duty time |
---|---|---|---|---|---|
Monitor guard positions |
PL e |
- |
3,7x10 -9 |
4 |
20 years |
Other terms
Product version number |
V4.0.0 |
Additional features |
Mounting plate |