Interlock MGB L0 APA AA1A2 S1 R 112596 Euchner Vietnam

Introduction Interlock MGB L0 APA AA1A2 S1 R 112596 Euchner Vietnam

MGB-L0-APA-AA1A2-S1-R-112596 (Order no. 112596)

Interlock module MGB-L0-APA..., without controller or indicator, RC18, on mounting plate

  • Interlock (no security lock)

  • With RC18 connector

  • Mounts on mounting plate

  • Unicode code table

Security lock type

MGB-L0...

The bolt blade in the handle module is moved in and out of the interlock module by activating the door handle. The door handle is not locked in the locked position.

Door hinge

The mechanical door stop is permanently integrated into the evaluation module of the MGB. Marking on the stop makes adjustment easier.

 

Instruction

LED indicators show all important system and status information.

 

Monitor output

FROM

ON when door is closed

OT

The bolt blade is installed into the evaluation module

Oh

Diagnose; there is an error

Notice

The interlock module is pre-assembled on the mounting plate.

Technical specifications Interlock MGB L0 APA AA1A2 S1 R 112596 Euchner Vietnam

Operational and display elements

Electrical connection value

Rated insulation voltage U i

30 V

Rated impulse withstand voltage U imp

1,5 kV

Time difference

 

between FO1A and FO1B

max. 10 milliseconds

Category of use

 

DC-13

24V 200mA

Risk period according to EN 60947-5-3

max. 350 milliseconds

Safety class

III

Transponder encryption

Unicode encoding

Pollution level (external, according to EN 60947-1)

3

 

Monitor OD, OT, OL, OI output

Output type

Semiconductor output, p-switched, short-circuit protection

Output voltage

UA-2V...UA V DC

Output current

max. 50 mA

 

Safety output FO1A, FO1B

Output type

Semiconductor output, p-switched, short-circuit protection

Output voltage

 

U FO1A /U FO1B HIGH

UB-2V...UBVDC

U FO1A /U FO1B LOW

0 ... 1 V DC

Output current

 

per safety output FO1A/FO1B

1 ... 200 mA

Check pulse duration

max. 0.3 milliseconds

Check the pulse interval

minute. 100 milliseconds

 

U A power source

DC operating voltage

 

you​

24V DC -15%... +10% 

Current consumption

 

I UA

max. 10 mA

 

U B power source

DC operating voltage

 

U B

24V DC -15%... +10% 

Current consumption

 

I UB

max. 80 mA

Mechanical and environmental value

Connection type

RC18 connector

Installation direction

Right DIN door hinge

Switch frequently

0,25 Hz

Mechanical life

 

in case of use as a door stopper and 1 Joule impact energy

0,1 x 10⁶

 

1 x 10⁶

Protection level

IP65

Ambient temperature

 

at U B = 24 V DC

-20 ... +55 ° C

Material

 

House

Fiberglass reinforced plastic; nickel-plated die-cast zinc; Stainless Steel

Characteristic values ​​according to EN ISO 13849-1 and EN IEC 62061

 

PL

Maximum SIL

PFH D

Type

duty time

Monitor guard positions

PL e

-

3,7x10 -9

4

20 years

Other terms

Product version number

V4.0.0

Additional features

Mounting plate

 

See more technical documents  here

See more technical products  here