Ultrasonic level transmitter AUL730 Alia Vietnam

Introducing the AUL730 Ultrasonic Level Transmitter Alia Vietnam

The AUL730 series  is an Ultrasonic Level Transmitter that is permanently attached to an airborne fixture and is used for non-invasive measurement.
Our user-friendly, microprocessor-based, field-programmable level measurement technique allows for zero process level disruption and low installation costs.

Features Ultrasonic level transmitter AUL730 Alia Vietnam

  • Simple setup and operation
  • Fast and simple to install and configure
  • The 4-20 mA output is powered by a loop with the HART signal
  • Low installation and operating costs
  • Non-contact level measurement
  • Exclusive sensor for level transmitter
  • Response time is less than 1 second

Technical specifications Ultrasonic level transmitter AUL730 Alia Vietnam

Measurement principles : Ultrasound level measurement
Measuring range : 0-3 m, 0-5 m, 0-10 m, 0-15 m, 0-20 m
  : 0-10 ft, 0-16 ft, 0-33 ft, 0-50 ft, 0-65 ft
Display : 4-line LCD with Bargraph (illuminated)
Resolution : 1 mm / 0,003 ft
Accuracy : +/- 0.25% of full scale
Repeatability : +/- 0.1% of reading
Material    
Ultrasound tube : ABS
Sensor head : Polyurethane (Standard) / ETFE / PTFE
House : ABS or aluminum alloy (Weather resistant)
  : Aluminum alloy (Explosion-proof)
Update time : <3 seconds
Ambient temperature : -20~60°C
Relative humidity : 0-100% RH
Sensor frequency : 80kHz / 40kHz / 30kHz
Empty space : 0,35-1,0m
Bean corner :
Keyboard : 4 keys have tactile action
Response time : Less than 1 second
Protection class : IP65 (ABS) / IP67 (Aluminum Alloy)
  : Explosion-proof, Ex d (ia) IIB T4
Setting : The 2" and 20 m G sensors are standard M70*2
  : Flange Head (Optional)
EMI/RFI effects : Follow SAMA PMC 33.1 from 20-1000
    MHz and for field strengths up to 30 V/m

 

Processing temperature : -40~60°C (Standard)
  : -40~100°C (Optional)
Process pressure : -0.8~2.0 G bars
Max. Cable length : 50 meters (Remote version)
Power supply : 12-36 VDC (2-Wire) (Compact)
  : Inrush current 25 mA (Standard)
  : Inrush current 40 mA (With HART)
  : 12-36 VDC / 85-260 VAC, 4 -Wire (Remote)
Energy consumption : Less than 3W
Output current : 4-20 mA (2 wire, 4 wire)
Payload : Rohm= (VDC-12) * 50 Ω
Warning output : High/Low/High-High/Low-Low (Remote control)
Communicate : RS485 MODBUS, 4 wires only (Standard)
  : HART signal (Optional)
Temperature. Compensation : Integrate to compensate
    Temperature range
Data saving : Operating parameters are stored by
    EEPROM for more than 10 years
Size    
Compact (ABS) : 105 mm (W) * 262 mm (H) * 168 mm (D)
Compact (Aluminum) : 161 mm (Width) * 247 mm (Height) * 132 mm (Depth)
Remote (ABS) : 183,5 mm (W) * 218 mm (H) * 125,5 mm (D)
Weight : 1.0 kg / 2.2 kg (Compact), 2.2 kg (Remote control)

 